beautypg.com

Caution – Brewer LiftMate User Manual

Page 11

background image

11

Document # 2102196 RevA

Preventative Maintenance

CAUTION

Failure to perform periodic inspections of the

LiftMate could result in personal injury or equip-

ment damage.

● Periodically inspect the electrical cord to ensure it is

free of cuts or damage.

● Periodically inspect the electrical cord to ensure it is

free of cuts or damage.

● Inspect the mechanical functions to ensure

satisfactory operation.

● Ensure that cord hooks are not loose. Remove outer

right shroud and tighten if necessary.

● Check shroud screws to make sure they are present

and tightened securely.

● Check platform bumper for damage, and to ensure

that it is secured to the edge of the platform. Reattach

or replace as necessary.

● Make sure the covers located at the back of the

platform when raised, are engaged with the guides,

and move freely when the platform is raised up and

down.

Casters

All casters will not extend or retract. This may indicate a low battery condition. Pressing any function on the Hand

Pendant will cause “Low Battery” light on Hand Pendant to illuminate, and beeping sound to occur. Charge bat-

tery. Note: plugging LiftMate into receptacle will resume all functions in a low battery conditon.If this action does

not resume functionality contact Brewer Customer Service at

1-888-Brewer1 (1-888-273-9371)

.

One caster will not extend or retract. Contact Brewer Customer Service at

1-888-Brewer1 (1-888-273-9371)

.

Casters are difficult to roll. Lay LiftMate onto its back on a carpeted or protective surface that will not damage

the finish. Check casters for wear, debris or damage. Clean or replace as needed. See the Service Parts list for

replacement kit number.

Casters causing marks on floor. Over time casters can get embedded with dirt redepositing it onto flooring. Lay

LiftMate onto its back on a carpeted or protective surface that will not damage the finish. Clean casters with soap

and water. Use a fine stiff wire brush with just enough force to remove dirt (use only if necessary). Use this op-

portunity to check casters for wear or damage. Replace as needed. See parts list for replacement kit number.

MAINTENANCE

TROUBLESHOOTING

CAUTION

The shroud material is resistant to most medicinal

type stains, but may be damaged by solvents and

dyes. Remove any spilled fluids from the shrouds,

painted surfaces or mat immediately.

● Clean the LiftMate weekly, wiping the painted metal

and plastic surfaces with a clean, soft cloth. If

desired, mild cleaners may be used.

● Clean the mat immediately after contact with any

fluids or gels. Use a mild soap and rinse with clear

water. Avoid the use of harsh chemicals as they can

permanently damage the finish. To prevent mat from

peeling do not allow it to remain wet.

Cleaning

Troubleshooting Continued...