Instructions:
Strip insulation 3/8” for 12 or 14 AWG wire. Strip insulation
7/16” for 16 or 18 AWG wire.
Hold stripped ends together in parallel and align any frayed
strands (do not twist wires).
Push wires firmly into connector. Twist connector clockwise
with fingers until tight. Pull wires to check for tightness.
Wire Connector / Combination Chart
One #14 w/one-to-four #16 or #18
One #12 w/one-to-three #14 or #16 or #18
Two #14 w/one-to-three #16 or #18
Two #12 w/one or two #14 or #16 or #18
You should now be able to use the rocker to manually turn
On/Off/Brighten the connected lighting.
Use your primary controller to include the dimmer switch in
the home control network after the dimmer switch is wired as
shown in the above diagram. It can then be added to groups
and/or lighting scenes and managed remotely to control
the On/Off status and brightness level of the connected
incandescent lighting.
Air Gap Switch
The 45607 has an air gap switch on the lower left side (see
diagram for location) to completely disconnect power to the
load. Pull the air gap switch OUT to disconnect the power and
push it all the way back in for normal operation. The air gap
switch must be all the way in for the dimmer to function and
control the lighting.
1.
2.
3.