Installation instructions, B4 three-conductor branch circuit connection – GE PT925DNBB User Manual

Page 9

background image

9

Installation Instructions

B4 Three-Conductor Branch

Circuit Connection

When connecting to a three-conductor branch
circuit, if local codes permit:

a. Connect the bare oven ground conductor

with the crimped neutral (white) lead to
the branch circuit neutral (white or gray
in color), using a wire nut.

b. Connect the oven red lead to the branch cir-

cuit red lead in accordance with local codes,
using a wire nut.

c. Connect the oven black lead to the branch

circuit black lead in accordance with local
codes, using a wire nut. If the residence
red, black or white leads are aluminum
conductors, see WARNING on page 8.

d. Install Junction Box Cover.

B3 New Construction and

Four-Conductor Branch
Circuit Connection

• When installing in new construction, or

• When installing in a mobile home, or

• When installing in a recreational vehicle, or

• When local codes do not permit grounding

through neutral:

a. Cut the neutral (white) lead from the crimp.

Re-strip the neutral (white) lead to expose the
proper length of conductor.

b. Attach the appliance grounding lead (green

or bare copper) in accordance with local
codes. If the residence grounding conductor is
aluminum, see WARNING on page 8.

c. Connect the oven neutral (white) lead to

the branch circuit neutral (white or gray) in
accordance with local codes, using a wire nut.

d. Connect the oven red lead to the branch

circuit red lead and the oven black lead to the
branch circuit black lead in accordance with
local codes, using wire nuts. If the residence
red, black or white leads are aluminum
conductors, see WARNING on page 8.

e. Install Junction Box Cover.

Ground
Wire

Junction Box
Cover

Junction Box
Cover

Ground and
Neutral Wires