Installation instructions, Cutout for 30, Single double oven under counter – GE PT925DNBB User Manual
Page 5: 2 cm)
5
NOTE: This oven is only approved
to be installed under the specifi c
models as labeled on this unit.
Installation Instructions
Cutout for 30”
(76.2 cm)
Single Double Oven
Under Counter
MUST SUPPORT 200 LBS. (91 Kg)
240V / 208V Junction Box Location
(junction box may be in adjacent cabinet)
Allow 1” (2.5 cm)
overlap top
of oven,
11/16” (1.8 cm)
overlap side edges of
cutout and
1 1/4” (3.2 cm)
overlap bottom
of oven.
Top and/or side fi llers
may be necessary
if unit is positioned
between existing cabi-
nets. Be sure
they are attached
securely, since they
will anchor the oven in
the cabinet.
Electric cooktops may be installed over this oven. See cooktop installation
instructions for cutout size. See label on top of oven for approved cooktop models.
28 1/2” (72.4 cm) Min.
28 5/8” (72.7 cm) Max.
27 1/4” (69.2 cm) Min.
27 5/16” (69.4 cm) Max.
A
36” (91.4 cm)
Typical
Countertop
Height
22” (55.9 cm) Min.
Above Support
Platform
9 1/2”
(24.1 cm)
Max.
25” (63.5 cm)
Must
match
toekick
height
4” (10.2 cm)
Typical
Toekick
3/4” (1.9 cm)
Support Platform
Required
Side by Side Installation
Install two wall ovens in separate cutouts.
24” (61 cm)
Cutout – observe all
dimensions and
requirements.
Center Line
30.5”
(77.5 cm)
Center Line
2” (5.1 cm) Min.
Cutout – observe all
dimensions and