NOTE: This oven is only approved
to be installed under the specifi c
models as labeled on this unit.

Installation Instructions

Cutout for 30

(76.2 cm)

Single Double Oven

Under Counter

MUST SUPPORT 200 LBS. (91 Kg)

240V / 208V Junction Box Location
(junction box may be in adjacent cabinet)

Allow 1 (2.5 cm)
overlap top
of oven,
11/16
(1.8 cm)
overlap side edges of
cutout and
1 1/4
(3.2 cm)
overlap bottom
of oven.

Top and/or side fi llers
may be necessary
if unit is positioned
between existing cabi-
nets. Be sure
they are attached
securely, since they
will anchor the oven in
the cabinet.

Electric cooktops may be installed over this oven. See cooktop installation
instructions for cutout size. See label on top of oven for approved cooktop models.

28 1/2(72.4 cm) Min.
28 5/8
(72.7 cm) Max.

27 1/4(69.2 cm) Min.
27 5/16
(69.4 cm) Max.

A

36(91.4 cm)
Typical
Countertop
Height

22(55.9 cm) Min.
Above Support
Platform

9 1/2

(24.1 cm)

Max.

25(63.5 cm)

Must
match
toekick
height

4(10.2 cm)
Typical
Toekick

3/4(1.9 cm)

Support Platform

Required

Side by Side Installation

Install two wall ovens in separate cutouts.

24(61 cm)

Cutout – observe all

dimensions and

requirements.

Center Line

30.5”

(77.5 cm)

Center Line

2” (5.1 cm) Min.

Cutout – observe all

dimensions and

requirements.