HP ProLiant BL280c G6 Server-Blade User Manual
Page 38

Hardware options installation 38
The HP Smart Array P712m Controller option does not support hard drive activity LEDs when installed in the
HP ProLiant BL280c G6 Server Blade.
Item
Description
1
HP Smart Array P712m Controller
2
SAS connector 2
3
SAS connector 1
4
Hard drive 2
5
Hard drive connector 2
6
Hard drive connector 1
7
Hard drive 1
8
Hard drive power connectors (2)
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
To install the component:
1.
Power down the server blade (on page
2.
Remove the server blade (on page
3.
Remove the access panel (on page
4.
If installed, disconnect the hard drive power and data cables from the system board ("
" on page
5.
Remove the air baffle.
6.
Do one of the following:
o
Remove the hard drive spacer from each hard drive bay.
o
Remove all SATA hard drives and hard drive spacers from each hard drive bay.
CAUTION:
When installing SAS hard drives in the server blade, always install the standard hard
drive screws provided with the server blade. Installing the long hard drive screws, located on the
hard drive spacer, can damage the hard drive.