HP XP Racks User Manual
Page 31
![background image](/manuals/398264/31/background.png)
Table 14 SNMP failure trap reference codes (continued)
Alert level
Section
Description
Trap reference code
SIM13
SIM23
SIM22
SERVICE
Failure with paired
volumes
A change to an S-VOL was received from the RCU (A
pair deletion was completed.)
xx
5x
DA
SERVICE
Failure with paired
volumes
A change to an S-VOL was received from the RCU (An
instruction to delete a pair was received in the Hold
status.)
xx
6x
DA
SERIOUS
Failure with paired
volumes
PAIR SUSPEND(RIO PATH CLOSE)
xx
0x
DC
SERIOUS
Failure with paired
volumes
PAIR SUSPEND(MVOL ERROR)
xx
1x
DC
SERIOUS
Failure with paired
volumes
PAIR SUSPEND(RVOL ERROR)
xx
2x
DC
SERIOUS
Failure with paired
volumes
PAIR SUSPEND(SUSPEND REPORT)
xx
4x
DC
SERIOUS
Failure with paired
volumes
PAIR SUSPEND(SIMPLEX REPORT)
xx
5x
DC
SERIOUS
Failure with paired
volumes
PAIR SUSPEND(COMMUNICATION ERROR AT RCU)
xx
6x
DC
SERIOUS
Failure with paired
volumes
PAIR SUSPEND(ERROR DETECTED AT RCU)
xx
7x
DC
SERVICE
Failure with paired
volumes
A volume being used by an S-VOL was suspended (PS
OFF on the MCU side was detected)
xx
8x
DC
SERIOUS
Failure with paired
volumes
ERASE FAIL
xx
9x
DC
SERIOUS
Failure with paired
volumes
Pair suspend (Spread by error of another Affiliate)
xx
Ax
DC
MODERATE
Failure with paired
volumes
UR M-JNL Meta overflow warning
xx
E0
DC
MODERATE
Failure with paired
volumes
UR M-JNL Data overflow warning
xx
E1
DC
MODERATE
Failure with paired
volumes
UR R-JNL Meta overflow warning
xx
E2
DC
MODERATE
Failure with paired
volumes
UR R-JNL Data overflow warning
xx
E3
DC
MODERATE
Failure with paired
volumes
The UR Read JNL was interrupted for one minute (A
failure on the MCU side was detected)
xx
F0
DC
SERIOUS
Failure with paired
volumes
The UR Read JNL was interrupted for five minutes (A
failure on the MCU side was detected)
xx
F1
DC
MODERATE
Failure with paired
volumes
The UR Read JNL was interrupted for one minute (A
failure on the RCU side was detected)
xx
F2
DC
SERIOUS
Failure with paired
volumes
The UR Read JNL was interrupted for five minutes (A
failure on the RCU side was detected)
xx
F3
DC
MODERATE
Failure with paired
volumes
URxUR M-JNL Meta full Warning
xx
F4
DC
MODERATE
Failure with paired
volumes
URxUR M-JNL Data full Warning
xx
F5
DC
SNMP failure trap reference codes
31