HP XP Racks User Manual
Page 26
Table 14 SNMP failure trap reference codes (continued)
Alert level
Section
Description
Trap reference code
SIM13
SIM23
SIM22
SERVICE
SVP failure
SI-MF/SI
02
F1
7F
SERVICE
SVP failure
UR
03
F1
7F
SERVICE
SVP failure
TI
04
F1
7F
SERVICE
SVP failure
FlashCopy (R)
05
F1
7F
SERVICE
SVP failure
Volume Migration
06
F1
7F
MODERATE
SVP failure
STANDBY SVP FAIL
xx
F2
7F
MODERATE
SVP failure
SVP FAIL OVER
xx
F3
7F
SERIOUS
License key
The term of validity is over
xx
F7
7F
SERIOUS
License key
The capacity of validity is over
xx
F8
7F
SERIOUS
License key
The PP is invalid by assumption PP invalidity
xx
F9
7F
SERVICE
SVP failure
Synchronization time failure
00
FA
7F
MODERATE
PS(DKU)
HDU POWER OFF
xx
50
AC
SERVICE
PS(DKU)
HDU power recovered
xx
51
AC
MODERATE
PS(DKU)
HDU power off(CL1)
xx
52
AC
MODERATE
PS(DKU)
HDU power off(CL2)
xx
53
AC
SERVICE
PS(DKU)
HDU power recovered(CL1)
xx
54
AC
SERVICE
PS(DKU)
HDU power recovered(CL2)
xx
55
AC
MODERATE
PS(DKC)
DKC was set to power error mode
00
60
AC
SERVICE
PS(DKC)
DKC was released from power error mode
00
61
AC
SERVICE
PS(DKC)
When DKC was set to power error mode, Urgent
Destaging start succeeded
00
62
AC
MODERATE
PS(DKC)
When DKC was set to power error mode, Urgent
Destaging start failed.
00
63
AC
SERIOUS
DKC environment
Server failure
0x
80
AC
SERIOUS
Drive
DB Validation error
00
90
AC
MODERATE
PS(DKU)
DBPS error
xx
50
AF
MODERATE
PS(DKU)
DBPS AC input error
xx
60
AF
MODERATE
DKC environment
SSW error
xx
80
AF
MODERATE
Battery
Battery charge EMPTY
xx
D1
AF
MODERATE
Cache
CM Backup mounting warning
xx
D4
AF
MODERATE
DKC environment
SSW data disagreement
xx
F0
AF
MODERATE
DKC environment
External temperature alarm
1x
1x
BF
MODERATE
PS(DKC)
SSVP voltage warning (PS_SUB)
xx
22
BF
MODERATE
PS(DKC)
SSVP voltage warning (SVP supply)
xx
23
BF
MODERATE
PS(DKC)
DKCPS warning
1x
4x
BF
MODERATE
PS(DKC)
DKCPS input voltage abnormality
1x
6x
BF
26
SNMP failure trap reference