Event Codes

Pager
Code


Server Event


Severity

21902

FCArray: Hard disk error found.

CRITICAL

21903

FCArray: Hard disk PFA condition found, drive may fail.

WARNING

21904

FCArray: An automatic rebuild has started.

INFORMATIONAL

21905

FCArray: A manual rebuild has started.

INFORMATIONAL

21906

FCArray: Rebuild completed.

INFORMATIONAL

21907

FCArray: Rebuild cancelled.

INFORMATIONAL

21908

FCArray: Rebuild stopped with errors.

CRITICAL

21909

FCArray: Rebuild failed due to new physical device.

CRITICAL

21910

FCArray: Rebuild failed due to logical device failure.

CRITICAL

21911

FCArray: A physical device failed.

CRITICAL

21912

FCArray: A physical device was found.

INFORMATIONAL

21913

FCArray: A physical device is gone.

INFORMATIONAL

21914

FCArray: A physical device is unconfigured.

INFORMATIONAL

21915

FCArray: Expand capacity started.

INFORMATIONAL

21916

FCArray: Expand capacity finished.

INFORMATIONAL

21917

FCArray: Expand capacity failed.

CRITICAL

21918

FCArray:Command to physical device timed out.

CRITICAL

21919

FCArray:Physical device command aborted.

CRITICAL

21920

FCArray:Command was retried.

INFORMATIONAL

21921

FCArray:Parity error.

INFORMATIONAL

21922

FCArray:Soft error.

INFORMATIONAL

21923

FCArray: Miscellaneous error.

INFORMATIONAL

21924

FCArray: Physical device reset.

INFORMATIONAL

21925

FCArray: A physical device became and active spare.

INFORMATIONAL

21926

FCArray: A physical device became a warm spare.

INFORMATIONAL

21927

FCArray: Request sense data present.

INFORMATIONAL

21928

FCArray: Consistency check started.

INFORMATIONAL

21929

FCArray: Consistency check completed with no errors.

INFORMATIONAL

21930

FCArray: Consistency check cancelled.

WARNING

21931

FCArray: Consistency check completed with an error.

CRITICAL

21932

FCArray: Consistency check failed due to logical device.

CRITICAL

21933

FCArray: Consistency check failed due to physical device.

CRITICAL

21934

FCArray: Logical device became offline.

CRITICAL

21935

FCArray: Logical device became critical.

CRITICAL

21936

FCArray: Logical device became online.

INFORMATIONAL

69