HP Server tc3100 series User Manual
Page 63

Appendix A
Event Codes
Pager
Code
Server Event
Severity
00705
Configuration Error in a Processor Slot
CRITICAL
00707
Processor failure
CRITICAL
00708
Processor (#) Disabled
CRITICAL
00709
Processor or Terminator was not detected
CRITICAL
00717
Processor problem
CRITICAL
00718
The Processor in the indicated slot has been disabled by the BIOS.
CRITICAL
00719
A single or multiple ECC Error has been detected on the P6 bus.
WARNING
0071X
CPU internal error
CRITICAL
0071X
CPU Thermal trip
CRITICAL
0071X
CPU hot warning
WARNING
00720
The Processor Card is missing or not properly terminated in
indicated processor module.
WARNING
00721
Voltage Regulating Module (VRM) on the indicated processor
module had failed.
CRITICAL
00725
CPU mismatch
CRITICAL
00800
Indicated Power Supply has been removed.
WARNING
00800
The indicated Power Supply has been inserted.
INFORMATIONAL
00801
Power supply unit power has failed.
WARNING
00802
Predictive failure/alert in Power supply
WARNING
00816
Redundant Power Supply: Subsystem warning temperature exceeded WARNING
00817
Temperature alert on designated Power Supply.
CRITICAL
00818
Redundant Power Supply: AC power source failure
CRITICAL
00819
Redundant Power Supply: Protection temperature exceeded, DC
shutdown
CRITICAL
00820
Redundant Power Supply: Protection temperature normal, power
restored
INFORMATIONAL
00821
Fan failure on designated Power Supply.
CRITICAL
00822
Fan speed-up on designated Power Supply.
WARNING
00823
A power supply's 3.3 volt supply has gone bad.
CRITICAL
00824
A power supply's 5 volt supply has gone bad.
CRITICAL
00825
A power supply's 12 volt supply has gone bad.
CRITICAL
00826
A power supply's -12 volt supply has gone bad.
CRITICAL
00900
Power supply subsystem redundancy gained.
INFORMATIONAL
00901
Power supply subsystem redundancy lost.
WARNING
00902
Power Supply Subsystem: Not enough Power Supply Units detected. CRITICAL
00904
Power System failure A/C Lost
CRITICAL
57