System board components – HP ProLiant xw460c Blade Workstation User Manual
Page 9
![background image](/manuals/397095/9/background.png)
Component identification 9
Online/activity LED
(green)
Fault/UID LED
(amber/blue)
Interpretation
Off Steadily
amber
A critical fault condition has been identified for this drive, and
the controller has placed it offline. Replace the drive as soon as
possible.
Off
Amber, flashing
regularly (1 Hz)
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
Off Off The drive is offline, a spare, or not configured as part of an
array.
System board components
Item Description
1
System board thumbscrew
2
Processor socket 2
3
Processor socket 1 (populated)
4
Hard drive backplane connector
5 FBDIMMs
(8)
6
Embedded NICs (2)
7
Mezzanine connector 1 [Type I mezzanine only (shown)]
8 Battery
9
Mezzanine connector 2 [Type I (shown) or Type II mezzanine]
10
System maintenance switch (SW2)
11
System board thumbscrew
12 Enclosure
connector
The symbols correspond to the symbols located on the interconnect bays. For more information, see the
HP ProLiant BL460c Server Blade Installation Instructions that ship with the server blade.