Sy s t e m I n f o r m at i o n : P a g i n g F e a tu re

23

Paging Feature

Your system may be set up to automatically send alert messages to a pager as certain conditions occur in your system.

• Your installer can program your system to send a message to your pager when any of the following events

occurs: arming (closing), disarming (opening), alarms, and trouble conditions.

• Messages transmitted to the pager will be 6 digits long and will display in the following format:

AAAABB

AAAA = System Account Number
Identifies which system transmitted the event. This is the same as the last 4 digits of your assigned ADT system
number.

BB = Event Identifier
Describes the type of event that has occurred on the system (i.e. closing). This will be one of the 4 basic event iden-
tifiers listed below:

91 = General Alarm Event

Indicates that an alarm has occurred on your system. This signal will be sent in the event of any zone,
emergency key (if enabled), or duress alarm.

81 = General Trouble Event

Indicates that a trouble has occurred on your system.

1X = Arming (Closing) Event

Indicates that the system has been armed. Users 01-08 will transmit 11-18 respectively and all other users
will report 19.

2X = Disarming (Opening) Event

Indicates that the system has been disarmed. Users 01-08 will transmit 21-28 respectively and all other
users will report 29.

e.g. 123425 = System disarmed by user 5 (account number of 1234)

NOTE:

The Reference Card below may be cut-out and carried with you for quick reference

PremisePro Paging Reference Card

91 = General Alarm Event

81 = General Trouble Event

1X = Arming (Closing) Event

2X = Disarming (Opening) Event

X = 1 to 8 for users 01-08 and 9

for users 09-32