HP Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem User Manual

Page 8

background image

Introduction 8

Interactive mode question/request

Description

Reference

Please enter action ("help\"

for list):

(required) Enter a command, or enter
help for a list of available

commands.

-a

Commands (on page

10

)

Please enter action:

(required) Asked if help was entered

for previous question. Enter a
command.

-a

Commands (on page

10

)

Please enter Onboard

Administrator IP Address:

(required for all commands except
discover and packageinfo) IP

address of the active OA in the

primary enclosure

Commands (on page

10

)

-i

Please enter Onboard

Administrator Username:

(required for all commands except
discover and packageinfo) User

name of the active OA in the primary

enclosure

Commands (on page

10

)

-u

Please enter Onboard

Administrator Password:

(required for all commands except
discover and packageinfo)

Password of the active OA in the
primary enclosure

Commands (on page

10

)

-p

Please enter starting IP

address:

(required) First IP address in the range
to search

discover

-s

Please enter ending address: (required) Ending IP address in the

range to search

discover

-s

Please enter firmware package

location:

(required) Full path to the Virtual

Connect package on the local

computer

packageinfo (on page

13

)

report (on page

13

)

update (on page

15

)

-l

Please enter the file location: (optional) Full path to the

configuration backup or support dump

file

configbackup
supportdump

-l

Please enter the Configuration

backup password:

(optional) Password for the

configuration backup file

configbackup

update (on page

15

)

-cp

Please enter Force Update

options if any (eg:

version,health):

Enter options separated by a comma. update (on page

15

)

-f

Please enter VC-Enet module

activation order if any (eg:

parallel or odd-even or serial

or manual. Default: odd-even):

Enter one of the following: parallel,

odd-even, serial, or manual

update (on page

15

)

-oe

Please enter VC-FC module

activation order if any (eg:

parallel or odd-even or serial

or manual. Default: serial):

Enter one of the following: parallel,
odd-even, serial, or manual

update (on page

15

)

-of

Please enter the time (in

minutes) to wait between

activating or rebooting VC-Enet

modules [max 60 mins. Default:

0 mins]:

Enter the time in minutes (maximum of

60 minutes).

update (on page

15

)

-we

Please enter the time (in

minutes)to wait between

Enter the time in minutes (maximum of
60 minutes).

update (on page

15

)

-wf