Update – HP Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem User Manual

Page 15

background image

Commands 15

Save support information:

vcsu -a supportdump -i 192.168.0.100 -u Administrator -p password -vcu

Administrator -vcp password

update

Update the firmware.
The user must provide the primary OA IP address, user credentials, and the package file to use for the
update.
The user can also force an update of modules in the following circumstances:

The target module contains a running firmware image that is the same version as the one in the source
package.

The target module contains a running firmware image that is newer than the version in the source
package.

The target module is in a degraded or failed state.

Item

Description

Syntax

vcsu -a update -i -u -p -l [-f ] -vcu

-vcp [-q] [-oe ] [-of ] [-we

] [-wf ] [-cp ]

Parameters:

IP

IPv4 address of the active OA in the enclosure*

USER

Name of the OA user with privileges to access all enclosure interconnect bays. Minimum
length is 1 character. Maximum length is 40 characters.**

PWD

Password of the OA user. Minimum length is 3 characters. Maximum length is 40

characters.**

FILE

Full path to the Virtual Connect package on the local computer or supported remote server

FORCE

Optional. Comma-separated list of force operations under certain conditions:

version—Allows an update of the same firmware version.

health—Allows an update on a module with failed or degraded health.

VCM USER

Name of the Virtual Connect user with Domain privileges. This command is required if an

enclosure is in a Virtual Connect domain. Minimum length is 1 character. Maximum length is
31 characters.

VCM PASS

Password for the Virtual Connect user. Minimum length is 3 characters. Maximum length is 31

characters.

-q

Optional. Specifies that the firmware update does not prompt for confirmation before
updating, and uses the default answer for the confirmation (YES).

-oe

Optional. Specifies VC-Enet module activation order. The following activation order methods

are supported:

parallel—All modules are activated at the same time.

odd-even—(Default) All modules on the backup VCM side are activated first, then all

modules on the primary VCM side except the primary VCM, then the primary VCM itself.

serial—Modules are activated one at a time, starting with the highest numbered bay.

manual—Modules are updated but not activated. Use the VC Manager GUI or OA GUI

to activate (reboot) modules.

-of

Optional. Specifies VC-FC module activation order. The following activation order methods

are supported:

parallel—All modules are activated at the same time.