Multiple enclosure guidelines, Enclosures view screen – HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 49

HP BladeSystem c-Class enclosures 49
connectivity can disable configuration attempts until the connectivity is re-estabilished and synchronized with
the domain. The Onboard Administrator IP addresses used must be configured to be static. The Onboard
Administrator user credential for all enclosures must be consistent to enable VCSU firmware updates for VC
modules in the remote enclosures. All FC-capable modules in the same horizontally adjacent bay pair (bays
1-2, 3-4, and so on) must be of the same type and position in all enclosures.
Multi-enclosure double-dense domains require similar and compatible VC-FC modules in bays 5, 6, 7, and
8 in all enclosures if FC connectivity is required. If a multi-enclosure double-dense configuration contains
incompatible VC-FC modules in bays 5, 6, 7, or 8 in the local or remote enclosures, some or all of the
compatible VC-FC modules in the remote enclosures might be designated INCOMPATIBLE after import.
Multiple enclosure guidelines
Observe the following guidelines when connecting multiple enclosures:
•
Each enclosure must have at least one VC-Enet, Flex-10, or FlexFabric module installed.
IMPORTANT:
In multi-enclosure configurations, HP 1/10 Gb VC-Enet Modules and HP 1/10
Gb-F Ethernet Modules are not supported for use as primary or backup modules.
•
All VC-Enet, Flex-10, or FlexFabric modules must be interconnected (redundantly stacked).
•
All enclosures must have the same FC and FlexFabric module configuration.
•
A single domain supports up to four c7000 enclosures.
•
When using multiple c7000 enclosures, there is a limit to the number of modules supported across the
enclosures within a domain. A total of 16 Ethernet and 16 VC-FC type modules can be installed. A
FlexFabric module counts as 1 Ethernet and 1 VC-FC module. Thus, up to 16 FlexFabric Modules or
combinations of FlexFabric, VC-Enet, and VC-FC modules are allowed as long as the 16-module limit
for each module type (Ethernet and FC) is not exceeded in the domain.
•
All Onboard Administrators and VC modules must be on the same lightly loaded and highly reliable
management Ethernet network and IP subnet.
•
VC modules must be running VCM v3.15 or higher.
•
The VC-FC and FlexFabric FC-configured uplink port configuration must be identical across all
enclosures.
•
The Onboard Administrator firmware must be version 3.11 or higher.
•
All Onboard Administrators must use the same user credentials because VCSU uses the primary
credentials for the remote enclosure.
•
When both Primary and Standby modules in the base enclosure are taken down for maintenance or
lose power and are no longer present in the domain, you will experience a loss of the management
capabilities in the VC domain. If there were network and fabric uplinks defined on the remaining
enclosures, the servers continue to have network and storage access. Both the Primary and Standby
modules in the base enclosure must be recovered to regain management access to the VC domain.
Enclosures View screen
This graphical representation consists of an enclosure front view and rear view. To display a window with
information about a particular device, mouse over that device in this graphical view.
- 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem