2.1.2 Recommended Installation Tools


You will need the following tools and equipment (not included) to install the IntraCore 3524 switch into an
equipment rack:

Flat head screwdriver

Phillips head screwdriver

Antistatic mat or foam

2.1.3 Power Requirements


The electrical outlet should be located near the IntraCore 3524 and be easily accessible. It must also be
properly grounded.

Make sure the power source adheres to the following guidelines:

Power: Auto Switching 110/240 VAC

Frequency range: 50/60 Hz

Maximum Input AC Current: 1.0A at 115 VAC full load

2.1.4 Environmental Requirements


The IntraCore 3524 must be installed in a clean, dry, dust-free area with adequate air circulation to maintain
the following environmental limits:

Operating Temperature: 0° to 40° C (32° to 104° F)

Storage Temperature: -20° to 70° C (-4° to 158° F)

Relative Humidity: 10% to 90% non-condensing

Storage Relative Humidity: 10% to 95% non-condensing


Avoid direct sunlight, heat sources, or areas with high levels

of electromagnetic interference.

2.1.5 Cooling and Airflow


The IntraCore 3524 uses internal fans for air-cooling. Do not restrict airflow by covering or
obstructing air vents on the sides of the switch.

2.2 Installation into an Equipment Rack


To install the unit in an equipment rack, use the following procedure:

Important! Before continuing, disconnect all cables from the IntraCore 3524.

1. Place the IntraCore 3524 on a flat, stable surface.
2. Locate a rack-mounting bracket (supplied) and place it over the mounting

holes on one side of the unit.

3. Use the screws (supplied) to secure the bracket (with a Phillips screwdriver).
4. Repeat the two previous steps on the other side of the unit.
5. Place the switch in the equipment rack.
6. Secure the switch by securing its mounting brackets onto the equipment rack

with the appropriate screws (supplied).


Important!
Make sure the unit is supported until all the mounting screws for each bracket are secured to the
equipment rack. Failure to do so could cause the unit to fall, which may result in personal injury or damage
to the unit.