Electrical Specifications

Electrical Specifications

20 Pound Capacity Models

Voltage Designation

Standard

Electric Heat

Code

Vo
lta

g

e

Cycle

Phase

Wir

e

Full Load

Amp

s

Ci
rc
ui

t

Brea

ker

AW

G

mm

2

Full Load

Amp

s

Ci
rc
ui

t

Brea

ker

AW

G

mm

2

2 Speed Models

B

120

60

1

2

16

20

12

4.0

N/A

C

380 – 415

50

3

4

4

15

14

2.5

14

15

14

2.5

F

440 – 480

60

3

3

4

15

14

2.5

N/A

J

200

50

3

3

5

15

14

2.5

N/A

O

208 – 240

60

3

3

5

15

14

2.5

23

30

10

6.0

Y

208 – 240

60

1

2

8

15

14

2.5

N/A

Variable-Speed Models

Q

200 – 240

50/60

3

3

4

15

14

2.5

21

30

10

6.0

R

380 – 480

50/60

3

3

4

15

14

2.5

N/A

X

200 – 240

50/60

1/3

2/3

6/4

15

14

2.5

N/A

NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.

Table 6

Electrical Specifications

30 Pound Capacity Models

Voltage Designation

Standard

Electric Heat

Cod

e

Vo
lta

g

e

Cy
cl

e

Phase

Wir

e

Full Loa

d

Amp

s

Circuit

Brea

ke
r

AW

G

mm

2

Full Loa

d

Amp

s

Circuit

Brea

ke
r

AW

G

mm

2

2 Speed Models

C

380 – 415

50

3

4

4

15

14

2.5

15

20

12

4.0

F

440 – 480

60

3

3

4

15

14

2.5

N/A

J

200

50

3

3

7

15

14

2.5

N/A

O

208 – 240

60

3

3

7

15

14

2.5

25

30

10

6.0

Y

208 – 240

60

1

2

10

20

12

4.0

N/A

Variable-Speed Models

Q

200 – 240

50/60

3

3

5

15

14

2.5

22

30

10

6.0

R

380 – 480

50/60

3

3

4

15

14

2.5

N/A

X

200 – 240

50/60

1/3

2/3

7/5

15

14

2.5

N/A

NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.

Table 7