Electrical specifications – Alliance Laundry Systems CHM1772C User Manual
Page 16
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Basic Installation/Operation
F8321401 (EN)
14
Electrical Specifications
Electrical Specifications
20 Pound Capacity Models
Voltage Designation
Standard
Electric Heat
Code
Vo
lta
g
e
Cycle
Phase
Wir
e
Full Load
Amp
s
Ci
rc
ui
t
Brea
ker
AW
G
mm
2
Full Load
Amp
s
Ci
rc
ui
t
Brea
ker
AW
G
mm
2
2 Speed Models
B
120
60
1
2
16
20
12
4.0
N/A
C
380 – 415
50
3
4
4
15
14
2.5
14
15
14
2.5
F
440 – 480
60
3
3
4
15
14
2.5
N/A
J
200
50
3
3
5
15
14
2.5
N/A
O
208 – 240
60
3
3
5
15
14
2.5
23
30
10
6.0
Y
208 – 240
60
1
2
8
15
14
2.5
N/A
Variable-Speed Models
Q
200 – 240
50/60
3
3
4
15
14
2.5
21
30
10
6.0
R
380 – 480
50/60
3
3
4
15
14
2.5
N/A
X
200 – 240
50/60
1/3
2/3
6/4
15
14
2.5
N/A
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
Table 6
Electrical Specifications
30 Pound Capacity Models
Voltage Designation
Standard
Electric Heat
Cod
e
Vo
lta
g
e
Cy
cl
e
Phase
Wir
e
Full Loa
d
Amp
s
Circuit
Brea
ke
r
AW
G
mm
2
Full Loa
d
Amp
s
Circuit
Brea
ke
r
AW
G
mm
2
2 Speed Models
C
380 – 415
50
3
4
4
15
14
2.5
15
20
12
4.0
F
440 – 480
60
3
3
4
15
14
2.5
N/A
J
200
50
3
3
7
15
14
2.5
N/A
O
208 – 240
60
3
3
7
15
14
2.5
25
30
10
6.0
Y
208 – 240
60
1
2
10
20
12
4.0
N/A
Variable-Speed Models
Q
200 – 240
50/60
3
3
5
15
14
2.5
22
30
10
6.0
R
380 – 480
50/60
3
3
4
15
14
2.5
N/A
X
200 – 240
50/60
1/3
2/3
7/5
15
14
2.5
N/A
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
Table 7