Connectionname, Hba_ww_id, Hostmode – HP ProLiant DL380 Server User Manual
Page 46: Acu scripting error messages, Connectionname hba_ww_id hostmode

ConnectionName
This option is a user-defined string used as the connection name for the specified HBA.
The string can consist of the following:
•
A maximum of 16 characters
•
Embedded space characters but cannot end with a space character
•
Any of the following characters: a–z, A–Z, 0–9, !, @, #, *, (, ), -, _, +, :, ., /, and [space]
HBA_WW_ID
This option specifies which HBA, based on its assigned WWN, is modified by the configuration
changes.
HostMode
This option specifies the HostMode for a selected HBA. Setting the Host Mode optimizes the storage
array for the selected operating system. The available host modes for an HBA are device-specific.
Not all modes are available on all devices. Not all HBAs support a HostMode.
The following operating system options might be available:
•
Default
•
Microsoft Windows
•
OpenVMS
•
Tru64
•
Linux
•
Solaris
•
Netware
•
HP-UX
ACU scripting error messages
Comment or clarification
Error message
Error code
The ACU process cannot be initiated. You might see this error
message if you are not authenticated to use ACU or if ACU
is already running.
General error.
1
ACU cannot save one or more controller configurations.
Error saving controller.
268
—
Controller is locked by another machine or
user.
278-282
—
Error communicating with controller.
290
An error occurred during the configuration process, but ACU
cannot identify the error because there is an internal ACU
error.
Internal error.
516
This error message occurs if you attempt to add an odd
number of drives to an array that has RAID 1 logical drives,
and the controller does not support RAID-level migration.
Array requires an odd number of drives.
1052
This error message occurs if a script that is running in
Reconfigure action mode lists fewer physical drives than
Cannot remove physical drives from
existing array.
1053
already exist in the array. ACU interprets this script as a
request to remove physical drives from an existing array, but
satisfying this request causes data loss, so ACU prevents the
script from running.
46
Toolkit utilities
- ProLiant BL465c Server Blade ProLiant BL2x220c G5 Server-Blade ProLiant BL2x220c G6 Server-Blade ProLiant SL390s G7 Server ProLiant BL280c G6 Server-Blade ProLiant ML370 Server ProLiant DL360p Gen8 Server ProLiant BL680c G5 Server-Blade ProLiant BL480c Server-Blade ProLiant DL370 G6 Server ProLiant SL230s Gen8 Server ProLiant SL250s Gen8 Server ProLiant SL335s G7 Server ProLiant BL260c G5 Server-Blade ProLiant DL365 G5 Server ProLiant BL490c G6 Server-Blade ProLiant BL460c Gen8 Server Blade ProLiant ML350 Server ProLiant DL160 Gen8 Server ProLiant DL585 Server ProLiant BL620c G7 Server-Blade ProLiant ML330 G6 Server ProLiant BL685c Server-Blade ProLiant DL320 Server ProLiant BL680c G7 Server-Blade Intelligent Provisioning ProLiant DL120 G7 Server ProLiant BL495c G6 Server-Blade ProLiant DL580 Server ProLiant DL380p Gen8 Server ProLiant BL2x220c G7 Server-Blade ProLiant DL785 G6 Server ProLiant BL460c Server-Blade ProLiant BL495c G5 Server-Blade ProLiant BL490c G7 Server-Blade ProLiant DL360 Server ProLiant ML310 G5 Server ProLiant DL385 Server ProLiant DL785 G5 Server ProLiant ML350p Gen8 Server