Micro doubler capacity deployment rules – ADC EDU-409 User Manual

Page 24

background image

Functional Description

150-409-115-05, Issue 5

18

January 26, 2000

EDU-409 List 1

M

ICRO

D

OUBLER

C

APACITY

D

EPLOYMENT

R

ULES

The deployment rules for micro doubler capacity are summarized below:

1

Use

Table 5 on page 13

for indoor enclosures.

2

Use

Table 6 on page 14

for outdoor enclosures with Full Solar Load for

ambient temperatures up to 46.1 °C maximum.

3

The capacities shown in

Table 6

can be increased by two for non-solar

load (shaded or manhole applications).

4

Decrease capacities in

Table 6

by one for every 2.7 °C increase, or

fraction thereof, in ambient temperatures above 46.1 °C.

5

Increase the capacities by one for every full +2.7 °C reduction in ambient
temperature below 46.1 °C.

6

Decrease any outdoor capacity by one for every four E1 repeaters, or
fraction thereof, that are installed with the doublers.

7

For all outdoor applications, decrease the capacity by one for every two
adjacent doublers that are not separated by at least one empty slot.