150-409-115-05, Issue 5

Functional Description

EDU-409 List 1

January 26, 2000

13

The capacities listed for the indoor enclosures in

Table 5

assume no solar

load. The capacities listed for the outdoor enclosures in

Table 6

assume a full

solar load as described above. The “Recommended Slot Assignment for
Maximum Capacity” column assigns slots according to the following thermal
stress reduction rules:

1

Always leave at least one empty slot between adjacent doublers. The
adjacency rule only applies to the left- and right-hand sides of the
doubler. The top of one unit can be adjacent to the bottom of another,
though the latter configuration should be avoided if possible.

2

Allow as much room as possible between doublers on all four sides.

Rule 1 does not apply to the HRE-458 and HRE-819 enclosures
since these products have the required slot separations
already built into their design.

Slot assignments that do not follow the recommended
configurations in

Table 5

and

Table 6

are permissible as long

as the above two rules are applied. Otherwise, damage may
occur to doubler units.

Table 5.

Indoor Enclosure Capacities

Vendor

Description

Model #

EDU-409 List
1 Doubler
Capacity

239 T1
Repeater
Capacity

CHARLES

Indoor wall mount

CiAC2300

7

7

CiAC2002

2

2

SPC

Indoor rack and wall
mount

4400-09

18

18