Indoor enclosure capacities – ADC EDU-409 User Manual
Page 19
150-409-115-05, Issue 5
Functional Description
EDU-409 List 1
January 26, 2000
13
The capacities listed for the indoor enclosures in
assume no solar
load. The capacities listed for the outdoor enclosures in
assume a full
solar load as described above. The “Recommended Slot Assignment for
Maximum Capacity” column assigns slots according to the following thermal
stress reduction rules:
1
Always leave at least one empty slot between adjacent doublers. The
adjacency rule only applies to the left- and right-hand sides of the
doubler. The top of one unit can be adjacent to the bottom of another,
though the latter configuration should be avoided if possible.
2
Allow as much room as possible between doublers on all four sides.
Rule 1 does not apply to the HRE-458 and HRE-819 enclosures
since these products have the required slot separations
already built into their design.
Slot assignments that do not follow the recommended
configurations in
are permissible as long
as the above two rules are applied. Otherwise, damage may
occur to doubler units.
Table 5.
Indoor Enclosure Capacities
Vendor
Description
Model #
EDU-409 List
1 Doubler
Capacity
239 T1
Repeater
Capacity
CHARLES
Indoor wall mount
CiAC2300
7
7
CiAC2002
2
2
SPC
Indoor rack and wall
mount
4400-09
18
18