beautypg.com

American Dryer Corp. ADG-464 User Manual

Page 84

background image

80

• If yes, wiring is OK:

• Check switch placement and door actuation.

• If no, check associated:

• Switch and wiring

• Check wiring back to the tumbler junction box

• Check wiring back to the Rear Controls

• Check PLC (Programmable Logic Controller)

Refer to wiring diagrams:

• Tumbler Junction Box Wiring Diagram
• Rear Panel Controls Wiring Diagram

• Retest; verify that the signal is operational

6. ”DRUM FAULT MESSAGE” Malfunction

a) PROBABLE CAUSES;

1a) Stop Motion Detector Module or Sensor.

2a) Wiring back to Main Electrical Enclosure

b) POSSIBLE SOLUTIONS;

Open the Main Electrical Enclosure locate input #0, 10 on the PLC (Programmable Logic Controller).
With control voltage “ON” (“GREEN” Push-Button), use the pendant to rotate the tumbler. Notice a
L.E.D. (light emitting diode) on as the tumbler (basket) is rotating.

If the L.E.D. is off, refer to paragraph 6 (section a) above.

1b) If the L.E.D. (light emitting diode) is off:

• Check Fuse #2; replace if necessary.

• Rotate the tumbler using the pendant control, and adjust the stop.

• Does the module’s L.E.D. (light emitting diode) respond?

• If yes, adjust the “Time Adjust” until the LED is on during rotation 12 to 15 seconds after.

• If no, check:

• Inductive Proximity Sensor for Damage