2. Electrical Service Specifications

IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is

affixed to the right side of the main electrical enclosure. In the case of 208 VAC or
240 VAC, the supply voltage must match the electric service specifications of the
data label exactly.

WARNING: 208 VAC and 240 VAC ARE NOT THE SAME. Any damage done to the dryer

components due to improper voltage will automatically VOID THE WARRANTY.

IMPORTANT: For proper sprinkler and dryer operation, sprinkler must be powered by a “separate

or dedicated” single-phase (1ø) multi-wire branch circuit at dryer’s nameplate voltage.

NOTE: For 4-wire service, cap the neutral.

NOTE: Contact the factory for electrical information not listed.

NOTE: ADC reserves the right to make changes in specifications at any time, without notice or

obligation.

ADG-464

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT:

NOTES: A.

B.

C.

208 VAC AND 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY.

Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed
appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/

verify correct breaker size according to appliance amp draw rating and type of breaker used.

Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

MINIMUM

WIRE SIZE

FUSING

CIRCUIT

BREAKER

Dual Element

Time Delay

60 Hz

50 Hz

208

3/4

107

--

*

150

150

240

3

104

109

*

150

150

380

3/4

--

60

*

90

90

400

3/4

--

60

*

90

90

416

3/4

--

57

*

90

90

460

3/4

52

--

*

80

80

480

3/4

52

--

*

80

80

* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes.