b) POSSIBLE SOLUTIONS;

1a) If the EMERGENCY STOP (E-Stop) - rear - does not respond:

• Verify that ALL other EMERGENCY STOP (E-Stop) buttons are pulled out.

• Verify that the rear panel’s disconnect plug is indeed connected. The disconnect plug is to allow

the removal of the rear panel for drying servicing.

2b) Defective EMERGENCY STOP (E-Stop) Switch

• Shut power off (main breaker) remove the rear panel and check switch using an OHM meter;

replace if defective.

• Retest

3b) Wiring Back to Main Electrical Enclosure

• Shut power to the AD-464 dryer (Main Breaker).

• Open “disconnects” on terminal #16 and terminal #17 of TB1; These disconnects are located on

the bottom of the main electrical enclosure.

• Connect an OHM meter to the output side of terminal #16 and terminal #17 of TB1.

• Push in the EMERGENCY STOP (E-Stop) button (opening the switch)

• Does the previous test show that there’s a switch closure opening?

• If yes, refer to paragraph 3b above.

• If no, refer to paragraph 4b below.

4b) Wiring from the EMERGENCY STOP (E-Stop) button to the main electrical enclosure is OK.

• Check REAR PANEL CONTROLS WIRING DIAGRAM

• Check TUMBLER JUNCTION BOX WIRING DIAGRAM

• See paragraph 3a above and retest

3. Rear Panel Control Problems

a) PROBABLE CAUSES;

1a) Rear Panel Disconnect Plug.

2a) Defective Switches.

3a) Wiring back to the main electrical enclosure.