• Check that “NONE” of the thermal and magnetic overloads have “TRIPPED.”

• Check circuitry; ADG-464 Main Panel Wiring Diagram

• Retest

7b) To verify burner fan motor contactor (MS8) operation:

Apply a 110 VAC voltage to MS8’s terminals A1 and A2 and verify that the contactor activates.

• If MS8 cycles this will indicate that its OK. Verify wiring to the device using the ADG-464 Main

Panel Wiring Diagram.

• If MS8 “DOES NOT” cycle;

• Check device and replace if necessary

• Retest

8b) Flame Detector & Burner Chassis Ground

To test the flame detector signal refer to Section VI, Part D, Gas Burner and Ignition System on
page 37 thru page 45.

• If the flame detector test fails:

• Verify that the flame detector and burner chassis connections, located on the left side if the burner,

are sound and tight.

• Check wiring (See AD-464 Main Electrical Panel Wiring Diagram and AD-464 Solenoid Junction

Box Wiring Diagram).

• Retest

9b) To test the burner controller module itself;

Refer to Section VI, Part D, Gas Burner and Ignition System on page 37 thru page 45 for
wiring information, concerning the Burner Controller Module (BCM), refer to the ADG-464 Main
Panel Wiring Diagram, the ADG-464 Solenoid Junction Box Wiring Diagram, and the ADG-464
Ladder Diagram.

5. “AIR FAULT” Message

PLC (Programmable Logic Controller)

MESSAGE “AIR FAULT”

a) PROBABLE CAUSES;

1a) Incorrect Fan (Blower) Rotation.

2a) Lint Chamber Air Pressure Switch.