72

• If 0 ohms (0

) is measured;

• Check RTD (Resistive Temperature Device)

• Check wiring to the RTD (refer to the main panel wiring diagram)

• Check wiring to the HI-LIMIT temperature controller (refer to the AD-464 Main Panel Wiring

Diagram).

• If RTD (Resistive Temperature Device) measures in the range of 100 ohms (100

);

• Check wiring to the HI-LIMIT Temperature Controller (refer to the AD-464 Main Panel Wiring

Diagram).

• If wiring checks out;

• Replace the HI-LIMIT Temperature Controller

• Retest

3b) If there is no display on the HI-LIMIT Temperature Controller:

• Check that main power is “ON;” front panel “BLUE” indicator.

• Check that ALL “EMERGENCY STOP” (E-Stop) buttons are disengaged (out).

• Check fuse 10’s blown fuse indictor.

• Check wiring; (refer to the AD-464 Main Panel Wiring Diagram).

• Retest

7. “DRUM FAULT” Message

PLC (Programmable Logic Controller)

MESSAGE “DRUM FAULT”

a) PROBABLE CAUSES;

1a) Stop motion detector module or sensor. With control voltage “ON” (“GREEN” push-button), use the

pendant control in “LOAD POSITION” to rotate the tumbler (basket).

NOTE: Input #0,10 on the

RTD (Resistive Temperature Device)

, stop the tumbler (basket) and wait for

device’s latched relay to de-energize. The time from when the tumbler (basket) stopped to the
relay de-energizing should be 15 to 20 seconds.

• If the de-energizing time is satisfactory, the unit is operating correctly;

• Check circuit wiring, and retest (refer to the AD-464 Main Panel Wiring Diagram).