Safety Devices

Location

Function

Computer

Display Message

Result of

Tripping

Load Door Switch

Left side of

Load door

Insures dryer load

doors are closed

"DOOR OPEN"

Dryer will not

run

Unload Door Switch

(2-Door Dryers Only)

Right side of

unload door

Insures dryer unload

doors are closed

"DOOR OPEN"

Dryer will not

run

Tilting Switches

Top left side

of base
module

Insures dryer is level

"LEVEL FAULT"

Dryer will not

run

Drum Rotation Sensor

Left side of

tumbler

section

Insures tumbler is

rotating

"DRUM FAULT"

Stops heat only

Lint Chamber Air

Pressure Switch

Center of

heat console

Insures proper air

flow through dryer

"AIRFLOW

FAULT"

Stops heat only

Burner Fan Air Flow

Switch

(Gas Dryers Only)

Center of

heat console

Insures proper

combustion air flow

into the burner box

"HEATER FAULT"

Stops heat only

Hi/Lo Gas Pressure

Switch

(Gas Dryers Only)

Lower left of

heat console

section

Insures proper gas

supply pressure for

adequate ignition

"GAS SUPPLY

FAULT"

Stops heat only

Heat Reclaimer
Damper Switch

Right Side of

heat console

Insures that the heat

reclaimer is either

opened or closed

Input LED #13 of

the PLC is off

None

Heat Console Door

Access Door Switch

Inside Heat

Console

Insures that access

doors are closed

"DOOR OPEN"

Dryer will not

run

Exhaust Air Temp

Control Sensor

Inside Burner

section duct

Monitors tumbler

exhaust air temp

"EXHAUST

DSFL"

Stops heat only

Exhaust Air Hi Temp

Control Sensor

Inside exhaust

duct

Monitors tumbler

exhaust and air temp

"HI-TEMP

FAULT"

Stops heat only

Intake Air Temp

Control Sensor

(optional)

Top right of

tumbler

section

Monitors tumbler air

intake temp

"INTAKE DSFL"

Stops heat only

Intake Air Temp

Control Sensor

Top right of

tumbler

section

Monitors tumbler air

intake temp

"HI-TEMP

FAULT"

Stops heat only

Burner Hi-Limit Safety

Sensor

Top of burner

section

Monitors air temp

above the burner box

"HI-TEMP

FAULT"

Stops heat only

Sprinkler Control

Safety Sensor

Top right of

tumbler

section

Open sprinkler

system water valve on

hi-temp condition

Orange sprinkler pilot

light comes on.

Alarm horn sounds

Opens the

srpinkler water

valve and power

down the whole

dryer

Lint Drawer Switches

Above lint

drawer

handles

Disables machine

when drawers are

open or if drawers

have not been

cleaned in last five

loads

Lint Drawer

Dryer will not

run