ADTRAN Express XLT User Manual
Page 147
![background image](/manuals/38144/147/background.png)
Appendix B: Log Messages
61200070L1-1
Express XL/XLT User Manual
131
Fallback to 56K
level 4
The Express XL/XLT is re-dialing the same destination at 56K call type be-
cause the 64K call type failed.
FarDN=
This is far-end directory number for an incoming call.
Hangup
A call from or to
ISDN line, then
Hold
The Express XLT has placed a call on hold. If no caller ID is available for the
ISDN line, then
Hold Reject
The Express XLT attempted to put a call on hold and it was rejected by the
ISDN switch. If no caller ID is available for the ISDN line, then
be blank for incoming calls.
Idle timeout
level 4
The Express XL/XLT’s idle timer has expired and the current session has
dropped.
L1 not up
level 2
A call attempt was stopped because ISDN layer 1 is down.
L2 not up
level 2
A call attempt was stopped because ISDN layer 2 is down trying to get first
TEI.