beautypg.com

Normal operation owner's guide – State GTS-240-NIH User Manual

Page 46

background image

46

Page

TEMPERATURE SETTINGS ON THE PCB

(WITHOUT REMOTE CONTROLLER)

There are 2 preset temperatures (120 °F (49 °C) and 140 °F (60 °C)) that you can select from by changing

the DIPswitch settings on the computer board without the remote controller. See the table below.

When the remote controller is in normal operation, the set temperature of the remote controller is given

priority over the set temperature of the DIPswitch settings.

Normal Operation

Owner's Guide

NOTE: Only change the switches with dark squares. The dark squares

indicate the direction the DIPswitches should be set to.

WARNING

• DO NOT adjust the upper bank of DIPswitches for the 540 (T-H3) models.

• Turn off the power supply to the water heater before changing the DIPswitch

settings.

• The temperature has been preset at the factory to 120 °F (49 °C).

Computer board

120 °F (49 °C)

DEFAULT

140 °F (60 °C)

No. 9 : OFF

No. 9 : ON

240 (T-H3J) and 340 (T-H3S) models

OFF

ON 1 2 3 4 5 6 7 8 9 10

OFF

ON 1 2 3 4 5 6 7 8 9 10

(Lower bank of DIPswitches)

120 °F (49 °C)

DEFAULT

140 °F (60 °C)

No. 5 : OFF

No. 5 : ON

540 (T-H3) models

OFF

ON 1 2 3 4 5 6

OFF

ON 1 2 3 4 5 6

2 3 4 5 6

Bank of

DIPswitches

Computer board

Upper bank of

DIPswitches

Lower bank of

DIPswitches

This manual is related to the following products: