Installation installation manual – State GTS-240-NIH User Manual

Page 10

background image

10

Page

Installation

Installation Manual

The pipe cover protects the plumbing pipes to

the water heater from unexpected adjustments.

This pipe cover is fixed to the bottom of the water

heater, which hides the plumbing and improves

the visual aspects of the whole installation for the

water heater.

The temperature remote controller has two

functions. It allows the output temperature

from the water heater to be adjusted within the

range of 100 °F to 185 °F, and it also works as a

diagnostic tool that will give a concise error code

whenever there is a problem with the unit. The

temperature options are 100 °F, 105 °F, 110 °F,

115 °F, 120 °F, 125 °F, 130 °F, 135 °F, 140 °F, 145

°F, 150 °F, 155 °F, 160 °F 165 °F, 175 °F and 185 °F.

See the Troubleshooting Section for information

on possible error codes.

1. Temperature remote controller:

9008172005 (TM-RE40)

3. Pipe cover: 9008331005 (TH-PC03)

4. Neutralizer kit: 9007607005 (TH-NT01)

The neutralizer assembly

neutralizes the condensate

(acidic water) that forms in the

secondary heat exchanger of the

water heater.

It connects to the condensate

drain port of the water heater by

using connectors included with

the neutralizer kit. Refer to p. 27

for the details.

6. 3" PVC

concentric termination: 9007611005 (TH-CVPVC33)

Used when terminating direct-vent (sealed combustion)

systems, with Indoor models that require a 3 in. (76 mm)

intake and a 3 in. (76 mm) exhaust. This concentric

termination provides the convenience of only having to

make one penetration through a sidewall instead of two

separate penetrations for the intake and exhaust piping. The

termination includes a bird screen, restricting small animals,

pests, and foreign objects from entering into the vent system.

2. 4” Backflow preventer and F-F adaptor:

9007996005

There are two functions available for this

adaptor, which can be connected with the water

heater and NovaVent venting line and prevents

the backflow of air through the exhaust vent.

This helps prevent harmful exhaust gases from

entering the home, as well as helping to prevent

the unit from freezing in areas where cold air

can be blown or drawn into the exhaust system.

Install this adaptor in accordance with the

installation instructions that are packaged with

the adaptor and any applicable codes.

5. Sidewall vent terminator (Hood) and Wall thimble:

They are used when venting out through the wall. These terminations are special stainless steel

vents for gas appliances and are UL listed as Category II, III and IV. For different wall thicknesses,

there are two ranges of lengths available. (Refer to the NovaVent brochure for details.) Install these

vent terminations in accordance with their installation instructions and any applicable local codes.

Covering wall thicknesses

Part#

Terminator Hood

9007999005

Wall Thimble 4 - 7 in.

9008345005

Wall Thimble 5 - 10 in.

9008346005

Termination + Thimble 4 - 7 in.

9008004005

Termination + Thimble 5 - 10 in.

9008005005

Wall Thimble

Terminator Hood