WARNING FOR INSTALLATIONS
FOR YOUR SAFETY, READ BEFORE INSTALLATION:
Do not install the heater where water, debris or
flammable vapors may get into the flue terminal.
This may cause damage to the heater and void the
warranty.
Do not have the vent terminal pointing toward
any opening into a building. Do not locate your
heater in a pit or location where gas and water
can accumulate.
Do not install this water heater under an
overhang less than 3 ft. (914 mm) from its top
or eaves. The area under an overhang must be
open to three sides (Outdoor models only).
Do not install the water heater vent terminator
within 1 ft. (305 mm) in the USA of any air intake
or building opening, and within 3 ft. (914 mm)
in Canada of any air intake or building opening
(Outdoor models only, refer to p. 20).
Do not install next to a dryer or any source
of airborne debris that can be trapped inside
the combustion chamber, unless the system is
direct-vented.
Prohibited
Prohibited
3 ft.
(914 mm)
1 ft. (305 mm) USA
3 ft. (914 mm) Canada
1 ft. (305 mm) USA
3 ft. (914 mm) Canada
1 ft. (305 mm) USA
3 ft. (914 mm) Canada