MAINTENANCE
Routine Inspection: Not required except for periodic inspection of the cable and connector to
ensure that these are neither damaged nor softened by incompatible liquid.
TABLE 1
ELECTRICAL CONNECTIONS
mV
4-20mA
0-10V
Type
Number
Connector
In+
Out+
Out-
In-
Earth
In+
In-
Earth
In+
Com
Out+
Earth
524-BP
Cable
R
Y
B
W
Drain
524-11
Cable
R
BL
Drain
524-2C
Cable
R
W
Y
Drain
Output
Supply Voltage
BP
0 to 100mV
10V d.c.
11
4 to 20mA
8 – 28V d.c.
2C
0 to 10V
13 to 28V d.c.
159 Swanson Road, Boxborough, MA 01719-1304
Tel: 800-257-3872 / 978-263-1400
OP524 Rev A 11/03
See also other documents in the category Setra System Sensors:
- Model ASM (8 pages)
- Model 204 (4 pages)
- Model 209 (4 pages)
- Model 227 (8 pages)
- 264 (4 pages)
- 269 (4 pages)
- Model 280E (4 pages)
- Model 370 (48 pages)
- Model 526 (7 pages)
- Model 540 (9 pages)
- Model 595 (8 pages)
- Model 869 (28 pages)
- Model 321 (4 pages)
- Model SRH (12 pages)
- Model Datum 2000 (31 pages)
- Model 217 (8 pages)
- Model 230 (12 pages)
- Model 242901-06 (1 page)
- Model 265 (4 pages)
- Model 270 (5 pages)
- Model 299 (4 pages)
- Model 470 (35 pages)
- Model 546 (8 pages)
- Model 730 (16 pages)
- GCT-225 (8 pages)
- Model 141 (4 pages)
- Model 205-2 (4 pages)
- Model 223 (8 pages)
- Model 231 (12 pages)
- Model 256 (8 pages)
- Model 276 (2 pages)
- Model 3100 (8 pages)
- Model 516 (6 pages)
- Model 550 (9 pages)
- Model 760 (18 pages)
- Model LD330 (4 pages)
- Model SRMD (8 pages)
- Model 201 (4 pages)
- Setra Model 206 (4 pages)
- Model 224 (8 pages)
- Model 231RS (16 pages)
- 260 (2 pages)
- 267MR (14 pages)
- Model 278 (2 pages)