3 specifications, 1 geomagnetic sensor characteristics, Specifications – PNI RM3100 Sensor Suite User Manual
Page 6: Geomagnetic sensor characteristics, Table 3-1: geomagnetic sensor performance
PNI Sensor Corporation
Doc 1017252 r03
RM3100 & RM2100 Sensor Suite User Manual
Page 5 of 45
3 Specifications
3.1 Geomagnetic Sensor Characteristics
Table 3-1: Geomagnetic Sensor Performance
1
Parameter
Cycle Counts
2
Units
50
100
200
Field Measurement Range
3
-800 to +800
T
Gain
20
38
75
LSB/ T
Sensitivity
50
26
13
nT
Noise
30
20
15
nT
Noise Density @ Max. Single-Axis Sample Rate
1.2
nT/ Hz
Repeatability over 200 T
15
8
8
nT
Hysteresis over 200 T
15
nT
Linearity over 200 T
0.5
%
Maximum Single-Axis Sample Rate
(divide by 3 for max. 3-axis sample rate)
1600
850
440
Hz
Single-Axis Average Current @ 24 Hz Sample
Rate (equivalent to 3-axis @ 8 Hz)
70
135
260
µA
Bias Resistor, R
b
121
External Timing Resistor for Clock, R
EXT
33
k
Circuit Oscillation Frequency
180
kHz
Operating Temperature
-40 to +85
C
Footnotes:
1. Performance values are typical. Performance specifications established with a supply voltage of
3.0 V, a bias resistor of 121
Ω, an external timing resistor of 33 kΩ, and with measurements taken
at room temperature. Other bias resistors, external timing resistors and operating voltages may
be used, but performance will differ from the values listed. Contact PNI for additional information.
2. The cycle count setting (eg. 50 ,100, and 200) is user-configurable and set in the Cycle Count
Registers. See Section 4.1 for a discussion on how the RM3100 works, and Section 5.1 for how
to set the Cycle Count Registers.
3. Field measurement range is defined as the monotonic region of the output characteristic curve.
Field measurement range can be extended using different bias resistors.