1.2 Always

- Read this guide in full before installing the product;
- Install the Thermat system with a regulating device;
- Use copper wires only;
- Perform the mandatory tests described in this guide and record readings on the

table of measures;

- Only use cement or an equivalent binder compatible with floor heating systems

(cement glue, ceramic glue, self-levelling cement);

- Ensure that the black heating cable is completely embedded in cement or an

equivalent binder (cement glue, ceramic glue, self-levelling cement);

- Ensure that the voltage supplied equals the nominal voltage of the Thermat

system;

- Repair the product only using the Thermat repair kit available at your authorized

Ouellet Canada Inc. dealer;

- Consult Ouellet Canada Inc.’s team of technical specialists for any questions

or for more information;

- Install Thermat at temperatures over 5 °C (40 °F);
- Heating cables must be at least 13 mm (½”) away from any open combustible surface.
- Metal structures or materials used for the support of or on which cables or sets

are installed be grounded in accordance with the National Electrical Code);

- The installer of series heating cable sets must inspect and remove damaged or

defective heating cable sets before they are covered or concealed;

- The installer of series heating cable sets must mark the appropriate circuit

breaker reference (label) indicating which circuit supplies the circuit to those
electric heating cables.