beautypg.com

4 installing the thermat floor heating system – Ouellet OTM User Manual

Page 16

background image

4.4 Installing the Thermat Floor Heating System

Tape, spray adhesive, stapler

Remove the product from the box and verify the electrical and insu-
lation resis tance of the heating cable.

- Unroll the mat, adhesive side down (fig. 4.4 a);
- Ensure that the cold lead is long enough to be connected to the thermostat

or junction box;

- To minimize floor height, chisel a 10 mm x 10 mm x 250 mm (3/8” x 3/8” x 10”)

channel in the subfloor to receive the cold lead/heating cable (black) junction.
The junction has an extra insulation sheath and a slightly larger diameter than
the heating cable;

- Continue to unroll the Thermat system on the floor, working around the

stationary elements marked out beforehand (see Section 4.4.1);

- As needed, reposition Thermat: its adhesive allows it to be positioned more

than once.

- You may use hot glue or tape to fasten the Thermat to the subfloor;

17

heating cable

junction

channel

cold lead

Fig. 4.4 a