Ouellet OTM User Manual
Page 13
4.1 Planning Work
Materials provided by Ouellet Canada Inc.
- Thermat floor heating system roll
- Installation instructions
- Electrical panel label
- Floor temperature sensor
Material required
- Temperature control with GFCI (available at Ouellet Canada Inc.)
- Cable check tester (available at Ouellet Canada Inc.)
- Stapler
- Protective glasses
- Measuring tape
- Broom
- Mop and bucket
- Felt marker
- Tape
- Hot glue gun
- Wood chisel
- Hammer
- Multimeter and megohmeter
- Electrician tools
- Electrical tape
For installation over a concrete slab, add the following:
- Spray adhesive
- Concrete chisel
Room Layout and Corresponding Thermat Product
- Create a room layout plan to scale (for maximum accuracy, use the Ouellet
Canada Inc form designed for this purpose);
- Identify all stationary elements (toilet, bath, shower, counters, drawers, and
permanent furnishings) and never install the heating cable under these
stationary elements (fig. 4.1);
- Determine thermostat or temperature control location;
- Note room dimensions;
- Determine cold lead location;
- Calculate the heating area in square feet (sq. ft.);
- Select the Thermat product from Table 2.1 to cover 80 % of the surface
or subtract a mimimum of 50 mm (2 in) around walls and stationary elements.
14
4.
In
st
al
la
tio
n
In
st
ru
ct
io
ns