BUS module: The module provides a selection of appropriate parameters for setting or displaying
special operating values. Parameters can be adapted using the NORDCON software or an
SK PAR-3H / -3E parameter box. Via PROFINET IO, all parameters can still be read and written via
the bus master.
Parameter [-Array]
Meaning
Remarks
-TU3-
-TU4-
-CU4-
P150
Set relays
Set DOUT directly or control via BUS
X
P151
External bus time-out
Monitoring of the SK xU4 bus module
X
X
P152
Factory setting
Reset module parameters
X
X
X
P153 [-01 …-02]
Minimum system bus
cycle
Reduction of the bus load on the system bus
caused by the module
X
X
P154 [-01 …-02]
Access to option card I/O
Administration of read and write rights to the IO of
the module
X
X
P160 [-01 … 04]
IP address
X
X
X
P161 [-01 …-04]
IP subnet mask
X
X
X
P162
Device name
Up to 240 characters (ASCII – Code 45 … 122),
save by entering "0" as the final character
X
X
X
P163 [-01 …-07]
Alarm test
Sets a diagnostic alarm
X
X
X
P170 [-01 … -02]
Present errors
Displaying module errors
X
X
X
P171 [-01 … -03]
Software version
Firmware version / Revision
X
X
X
P172
Configuration
Module type
X
X
X
P173
Module status
Status of system bus or the connected FI
X
X
X
P174
Status of digital inputs
Image of the switching status of DIN
X
X
P175
Digital output state
Image of the switching status of DOUT
X
P176 [-01 … ]
Process data bus In
Information parameter
X
X
X
P177 [-01 … ]
Process data bus Out
Information parameter
X
X
X
P178
Internal temperature
Information parameter
X
P180 [-01 … -07]
PPO-Type
Information parameter
X
X
X
P181 [-01 … -06]
MAC address
Information parameter
X
X
X
P185 [-01 …-04]
Present IP address
Information parameter
X
X
X
P186 [-01 …-04]
Current IP subnet mask
Information parameter
X
X
X
Pos : 29 /T echnisc he I nf ormati onen/ SK xU x - Bus - Erweit erungen/ Allgemei n - Syst emübergreifend/ Par ameterz ugriff und Di agnose [ Bus BG - Allgemei n] @ 3\ mod_1363794074590_388. doc x @ 61915 @ 5 @ 1
Parameter access and diagnosis
The NORD CON software and optional control units such as the SK PAR-3H parameter box provide
convenient access to the parameters of the module and allow status information to be read out.
SK TU3-
SK TU4-
SK CU4- / SK TU4-
Access via RJ12-SK 5xxE
diagnosis socket
Access via RJ12-Bus diagnosis
socket -
connection unit
SK TI4-TU-BUS(-C)
Access via RJ12-Frequency
inverter diagnosis socket , if
connected to module via system
bus.
Pos : 30 /T echnisc he I nf ormati onen/ SK xU x - Bus - Erweit erungen/ PROF INET IO / Weit erf ühr ende D okument ationen und Sof t war e [ SK CU4- PNT] @ 4\ mod_1385375409589_388. doc x @ 106528 @ 5 @ 1
Further Documentation and Software
Software
Name
Software
Meaning
GSDML file
Device characteristics and parameters
NORD CON
Parameterisation and diagnostic software
Document
Name
Document
Meaning
BU 0000
Description of NORD CON software
BU 0200
SK 2xxE frequency inverter manual
BU 0040
ParameterBox manual
BU 0290
Description of PROFINET IO bus communication
BU 0180
Frequency inverter manual SK 180E, SK 190E
=== Ende der List e f ür T ext mar ke I nhalt ===