NORD Drivesystems TI 275271015 User Manual
Technical information / datasheet, Sk cu4-pnt, Notice

Technical Information / Datasheet
PROFINET IO Bus module
SK CU4-PNT
1.0
Erstausgabe / first issue
4913
Rck
TI 275271015
GB
version
reason for change(s)
issue
name
document
speech
Pos : 2 /T ec hnis che Inf or mationen/ SK xU x - Bus - Er wei ter ung en/ PR OFIN ET I O/ SK C U4-PN T / 275271015 / Basisinf or mationen [SK CU 4-PNT ] @ 4\ mod_1385369288406_388.doc x @ 106351 @ 555 @ 1
SK CU4-PNT
Part number: 275 271 015
PROFINET IO
®
- Internal Bus – Interface
NOTICE
Validity of this document
This document is only valid in combination with the operating instructions for the relevant frequency inverter. All
of the information that is relevant for a safe start-up of this module and the frequency inverter is only available
under these conditions.
Scope of delivery
1 x
Module
SK CU4-PNT
1 x
System bus cable set
grey / black
1 x
24 VDC cable set
brown / blue
2 x
Connecting screws
M4 x 20, cross-head
Field of use
Internal interface for the connection of a decentralised frequency inverter (SK 180E … SK 2xxE) to a
PROFINET IO field bus. This is connected to the inverter via the system bus and can directly access
up to 4 frequency inverters. 2 digital inputs are available.
Technical data
Module
Temperature range
-25°C … xx °C *
Vibration resistance
3M7
Temperature class
Class 3K3
Firmware version
V1.2 R0
Protection class
IP20
Hardware version
AA
Supply voltage
24 V ± 20
%, ≈ 100 mA
Reverse polarity protected
* The upper temperature limit depends on the frequency inverter and the operating mode
à see "Derating"
Digital input - working range
Low: 0 V … 5 V, High: 15 V … 30 V
Digital input - specific data
R
i
= 10 kΩ, input capacity: 10 nF, response time 3 ms,
inputs as per EN 61131-2 type 1