5. Motors with ignition protection
class "increased safety Exe"
Painting: The motors are supplied with a maximum paint thickness of 0.2 mm in order to prevent electrostatic
charging. In case of repainting, the total thickness of the paint layer, including the original painting, must not
exceed 0.2 mm.
Type plate for NORD Exe motors according to EN 60079
Explanation of the standard details on the type plate
EN 60034 (H), (A)/ EN 60079
Standard series used for explosion protection
(Please note the Declaration of Conformity)
Voltage range A according to EN 60034-1
Half key balancing according to EN 60034-14
Product standard
1
Data Matrix Code
9
Operating mode
17
Explosion protection labelling
2
Code number of the designated
body
10 Details
of
standards
18
Start-up current/nominal current
3
Number of phases
11
Nominal frequency
19
t
E
- time
4
Type designation
12 Nominal
voltage
20
Note: TMS with statement of the t
A
time only
with PTC tripping device according to
DIN 44082
5
Order number / motor number
13
Permissible voltage range
21
Notice ! Observe operating instruction
B1091.
6
Year of manufacture:
14 Data
sheet
number
22
Nominal power
7
Temperature class
15
Power factor
23
Nominal current
8
Housing protection type
16 Speed
24
Individual serial number