beautypg.com

Dwyer instruments, inc – Dwyer UHH User Manual

Page 8

background image

File names can be scrolled through and their data viewed by selecting VIEW.
Calculated statistics of the data from a file are viewable such as average or peak
and valley by selecting STAT. A file may be deleted by hitting DELETE. To exit this
screen and return to the previous, press the left arrow key.

The following will appear after hitting VIEW from the saved files list. Numerical
order value in the saved group along with its file name and format, the DATE, TIME
of that data point and the parameter data values recorded. To scroll through each
data point's information within a file, press the navigation keys. Any data
point may be deleted in their respective file by pressing DEL.

After selecting STAT from the saved file list screen you will see statistics for all data
within the respective file. Average, Peak and Valley will be visible for all parameters.
The soft key under MORE will display additional parameters if available.

Low Battery Warning
The low battery level screen will appear when the UHH detects its charge to be
nearing an end. The lithium ion polymer battery is expected to provide
approximately 1000 full charge cycles over its lifespan. Once the battery has
exceeded its useful lifespan, due to varying regulations regarding shipping lithium
batteries, please contact Dwyer Instruments Inc. for details.

MAINTENANCE/REPAIR
Upon final installation of the Series UHH, no routine maintenance is required. The
Series UHH is not field serviceable. Contact Dwyer Instruments Inc. for return
details (field repair should not be attempted and may void warranty).

WARRANTY/RETURN
Refer to “Terms and Conditions of Sales” in our catalog and on our website. Contact
customer service to receive a Return Goods Authorization number before shipping
the product back for repair. Be sure to include a brief description of the problem
plus any additional application notes.

Low Battery Warning

Lithium ion polymer batteries are very volatile and can cause a
fire if punctured or severly damaged. Only use a Dwyer

Instruments, Inc. approved charging device in a well ventilated area away from any
flammable materials or gases. Do not incinerate. Only charge between 32 to 113°F
(0 to 45°C).

WARNING

ACCESSORIES

Model
AP1

RP1
VP1

AP2
RP2
VP2

UHH-STRAP
UHH-ICHRG
UHH-CBL
UHH-SD
UHH-C1
UHH-C2

Description
Thermo-anemometer air velocity & temperature probe with coiled
cable
Thermo-hygrometer & temperature probe with coiled cable
100 mm vane thermo-anemometer air velocity, temperature,
humidity probe
Wireless thermo-anemometer air velocity & temperature probe
Wireless thermo-hygrometer humidity & temperature probe
Wireless 100 mm vane thermo-anemometer air velocity,
temperature, humidity probe
UHH hand strap
UHH charger with international adapters
USB cable
2GB SD card
Soft carrying case
Heavy duty hard case with pre-cut foam inserts for additional
sensor storage

DWYER INSTRUMENTS, INC.

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.

Fax: 219/872-9057

e-mail: [email protected]

©Copyright 2014 Dwyer Instruments, Inc.

Printed in U.S.A. 5/14

FR# 02-443875-00 Rev. 6

It is required before the initial use of the module to fully charge
the battery for 12 hours.

NOTICE

List of Log Files

VIEW of Saved Files

STAT (Statistics) of a Saved File

If there are many stored data points on a file, some time may
elapse before the statistics shown above appear.

NOTICE