Iv. specifications – Dwyer PMT User Manual
Page 5
Particulate Monitoring Systems
Installation & Operating Manual
Document No. 209-1026-E
v
©2007
IV. Specifications
ELECTRICAL
PARAMETER DETAIL
SPECIFICATION NOTE
Measurement Units
picoamperes (pA)
1 x 10 ⎯ ¹² Amp
Standard
10.0pA – 5000pA
Measurement Range
Optional
5.0 and 0.5pA – 5000pA
Accuracy
± 5% of Range
Full Temp Range
Operating
-15F to +160F (-25C to +70C)
Ambient Temperature
Range
Storage
-40F to +185F (-40C to +85C)
Digital Filtering
Range
Ajustable 0.5 Sec – 60 Sec
Isolation
500VDC Process to Loop
Output
Compliance
Max. RLoad = (Vsupply–18V)/0.02A
(24VDC = 300Ohm Rload Max.)
Scale
Linear or Logarithmic
4-20mA Output
pA Range
0-100, 0-500, 0-1000, 0-5000 Linear
0.5–500, 5–5000 Logarithmic
MECHANICAL
Standard
½” NPT Mount
Mounting
Optional Tri-clamp,
Flange
Other, consult
factory
Sensor
Teflon over Stainless
Materials
Body Stainless
Steel
-40F to +250F (-40C to +120C)
-40F to +450F (-40C to +232C)
Process Temperature
Range
Operating
-40F to +800F (-40C to +427C)
two piece
configuration
only
Pressure Range
Operating
Full Vacuum to 10PSI
Other, consult
factory
Type
Painted Cast Aluminum
Enclosure
Rating
NEMA 4X (IP 66)
OPERATING and APPLICATION RANGE
10.0pA
5.0pA
Optional
At least 10.0-5000 mg/m³
At least 0.004 to 2.0 gr/cf
At least 5.0 – 5000 mg/m³
At least 0.002 to 2.0 gr/cf
Visible
Barely Visible
To Visible
Particle Concentration
(Approximate Guide)
0.5pA
Optional
At least 0.5 to 500 mg/m³
At least 0.0002 to 0.2 gr/cf
Barely Visible
To Invisible
Particle Velocity
300 ft/min. (91 m/min.) and Higher
Particle Size
0.3 Micron and Higher