Sch 40 Wrought Steel Pipe Per ANSI B36.10

Height
“H”

5.544

5.489

5.400

5.327

5.269

5.210

5.087

4.964

4.730

4.483

4.250

4.100

3.850

3.600

3.375

2.900

K-FACTOR
PULSES/ U.S.
Gallon

55.45

37.47

27.82

17.77

13.04

9.92

6.05

4.02

2.18

1.30

0.88

0.71

0.53

0.41

0.32

0.22

K-FACTOR
PULSES/LITER

14.650

9.900

7.350

4.695

3.445

2.621

1.598

1.062

0.576

0.343

0.232

0.188

0.140

0.108

0.085

0.058

Pipe
Size

1.5

2

2.5

3

3.5

4

5

6

8

10

12

14

16

18

20

24

Sch 80 Wrought Steel Pipe Per ANSI B36.10

Height
“H”

5.500

5.438

5.342

5.260

5.196

5.130

4.994

4.842

4.588

4.300

4.025

3.850

3.575

3.300

3.025

2.750

2.575

K-FACTOR
PULSES/ U.S.
Gallon

61.86

42.19

31.41

20.00

14.61

11.08

6.71

4.51

2.41

1.45

0.98

0.79

0.59

0.45

0.36

0.29

0.24

K-FACTOR
PULSES/LITER

16.343

11.147

8.299

5.284

3.860

2.927

1.773

1.192

0.637

0.383

0.259

0.209

0.156

0.119

0.095

0.077

0.063

Pipe
Size

1.5

2

2.5

3

3.5

4

5

6

8

10

12

14

16

18

20

22

24

K-FACTOR
GPM/mA

9.91

16.34

23.31

35.99

48.14

61.98

97.40

140.7

243.6

383.9

621.6

658.6

860.4

1089

1353

1957

K-FACTOR
LPM/mA

37.51

61.85

88.24

136.2

188.2

234.6

368.7

532.6

922.1

1453

2353

2493

3257

4122

5122

7408

Current Output

Pulse Output

Current Output

Pulse Output

K-FACTOR
GPM/mA

4.626

14.38

20.64

32.16

43.27

55.97

88.58

126.9

222.3

349.6

494.7

597.5

783.2

994.1

1230

1492

1778

K-FACTOR
LPM/mA

17.50

54.43

78.13

121.7

163.8

211.9

335.3

480.4

841.5

1323

1973

2262

2965

3763

4656

5648