Dwyer instruments, inc – Dwyer IS626 User Manual
Page 4
©Copyright 2009 Dwyer Instruments, Inc.
Printed in U.S.A. 12/09
FR# 00-443528-00 Rev. 3
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000
www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A.
Fax: 219/872-9057
e-mail: [email protected]
NOTES:
1. MAX SAFE AREA VOLTAGE NOT TO EXCEED 250 VAC.
2. NO REVISIONS WITHOUT PRIOR UNDERWRITERS LABORATORY APPROVAL.
3. (ENTITY CONCEPT DEFINITIONS)
THE ENTITY CONCEPT ALLOWS INTERCONNECTION OF INTRINSICALLY SAFE APPARATUS TO ASSOCIATED APPARATUS
NOT SPECIFICALLY EXAMINED IN SUCH COMBINATION. THE CRITERIA FOR INTERCONNECTION IS THAT THE VOLTAGE AND
CURRENT WHICH INTRINSICALLY SAFE APPARATUS CAN RECEIVE AND REMAIN INTRINSICALLY SAFE, CONSIDERING FAULTS, MUST BE
EQUAL TO OR GREATER THAN THE VOLTAGE (Voc) AND CURRENT (Isc) LEVELS WHICH CAN BE DELIVERED BY THE
ASSOCIATED APPARATUS. CONSIDERING FAULTS AND APPLICABLE FACTORS. IN ADDITION, THE MAXIMUM UNPROTECTED CAPACITANCE AND
INDUCTANCE (Ci & Li) OF THE INTRINSICALLY SAFE APPARATUS. INCLUDING INTERCONNECTING WIRING. MUST BE EQUAL TO OR LESS THAN
THE CAPACITANCE AND INDUCTANCE WHICH CAN BE SAFELY CONNECTED TO ASSOCIATED APPARATUS.
4. INSTALLATION MUST BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NFPA 70, ARTICLE 504) AND ANSI/ISA-RP12.6.
IMPORTANT! NO REVISIONS WITHOUT
PRIOR UNDERWRITERS LABORATORIES
APPROVAL CAN BE IMPLEMENTED
0 1 - 7 0 0 7 9 7 - 0 0
01-700797-00
HAZARDOUS (CLASSIFIED) LOCATION
INTRINSICALLY SAFE
FOR CLASS I DIV.1 GROUPS A,B,C,D
CLASS II DIV. 1 GROUP E,F,G
CLASS III DIV. 1
T4 TEMPERATURE CODE BASED ON 80˚C AMBIENT
NONHAZARDOUS LOCATION
ASSOCIATED APPARATUS
WITH ENTITY PARAMETERS
RED
OR PIN 1
IS626, PBLTX OR SBLTX SERIES
TRANSDUCERS
BLACK
OR PIN 4
V
max
= 28VDC
I
max
= 93mA
C
i
= .051µF
L
i
= 240µH
P
i
= 0.651W
CATALOG NUMBERS:
IS626-aa-bb-cc-dd-ee-ffff
PBLTX-aaa-bbb-cccc
SBLTX-aa-bb-cccc
WHERE:
a,b,c,d,e & f = ANY LETTER OR NUMBER
BULLETIN ARTWORK
INTRINSIC SAFETY
CONTROL DRAWING FOR
IS626, PBLTX & SBLTX SERIES
S C A L E 1 : 1
3
F R . N O .
V
oc
≤ 28 V
I
sc
≤ 93 mA
C
a
≥ 0.051 µF + C
CABLE
L
a
≥ 240 µH + L
CABLE
P
o
≤ 0.651W
CD = CRITICAL DIMENSION
STANDARD TOLERANCES UNLESS NOTED:
ALL DECIMAL DIMENSIONS ± .005
ALL ANGLES ± 1˚
1
NO.
ADDED LABELS TO PLUS & MINUS TERMINALS.
ADDED Pi & Po = 0.651W TO BOXES. ECR #21141.
CHANGES
BY/DATE
DATE
7-14-06
DATE
7-14-06
DWN BY
DGH
CHKD
CAT
APPD
SE
NAME
ACAD2002
MATERIAL
FINISH
NOTICE: This drawing and the principles and elements of design embodied therein are the exclusive property of DWYER INSTRUMENTS, INC. and are not
to be communicated, disclosed, reproduced or used except as previously authorized in writing by such corporation and must not be submitted to outside
parties for examination without the written consent of said corporation.
BRENT
1-22-07
2
Project3:Layout 3 12/7/09 11:21 AM Page 4