beautypg.com

Wiring diagram: testing and operation, Specifications – Aiphone JF-DVF-HID User Manual

Page 2

background image

JF-2MED

JF-DVF-HID

PS-1820UL

+

-

+

-

1A1

1A2

B1

B2

2A1

2A2

S

S

A1

A2

WIRING DIAGRAM:

TESTING AND OPERATION:

When power is applied to the card reader, the LED will flash green three (3) times while
the beeper beeps simultaneously. The LED will then turn red. This indicates that the
microcontroller is operating properly.

Present an ID card to the reader. (Hold card directly in front of reader.) The LED will
momentarily turn green while the beeper beeps once, indicating that the card was read
successfully.

CARD READER:
Power Source:

5 ~ 16V DC

Absolute Max. Voltage: 18V DC
Current Requirements: 30mA (Avg); 75mA (peak)
Terminations:

Color-coded pre-wired pigtail

Wiring Distance:

500'

Operating Temperature: -10°~60°C / 14°~140°F
Operating Humidity:

0-95% relative humidity
non-condensing

SPECIFICATIONS:

CAMERA:
Camera unit:

CCD Camera

Scanning line:

525 lines

Min. illumination:

5 Lux at 1' or less

Terminations: Screw

terminals

Operating Temperature: -10°~60°C / 14°~140°F
Wiring Distance:

330' w/871802 wire
980' w/JBW-BA & 851602 wire

Dimensions(camera):

5-¾” W x 11-⅝” H x 1-5/16" D

With SBX-DVF-P:

5-15/16" W x 11-¾” H x 2-13/16" D (Top)
1-15/16" D (Bottom)

Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071

Pg. 2

JF-DVF-HID Instr.

0810JD

FCC WARNING:

This device complies with Part 15 of the FCC rules.

Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may cause undesired operation.

For proper regulatory compliance, the drain wire should be disconnected at the
power supply end of the cable.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
The Reader is intended to be powered from a limited power source output of a
previously certified power supply.

TOLL FREE TECHNICAL SUPPORT:

(800) 692-0200

E-MAIL: [email protected]

Wiegand Wire Color
+ DC (5-16V)

Red

Ground

Black

Data0

Green

Data1

White

Shield Ground

Drain

Green LED

Orange

Red LED

Brown

Beeper

Yellow

Hold

Blue

Card Present

Violet

Connect the reader to the host according to the
wiring table below and the host installation guide.