Maintenance, Continued) – Blue Angel Pumps BSP45 User Manual

Page 6

background image

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

Pump won’t run

Motor hums but
pump won’t run

Pump runs but
pumps very little
or no water

Pump cycles too
frequently

No yellow light

Red light is on
with alarm

6

Operating Instructions and Parts Manual

www.blueangelpumps.com

1. Check all connections
2. Check battery and replace if low or defective
3. Make sure nothing is interfering with operation of switch

4. Check internal fuse located on the PS/BC. Pull the charger from

the wall outlet and remove. If the fuse is blown, replace it with
an automotive type fuse of the same amp ratio.

1. Check battery and replace if low or defective
2. Unplug pump, volute, and check to see if impeller is free to turn.

If impeller is locked, remove the obstruction. Reassemble pump
and reconnect

1. Check to make sure check valves installed between primary

pump discharge and Backup Sump Pump are functioning
properly

2. Check for obstruction and clear if necessary

3. If discharge is too high, a separate line may be required with a

lower discharge height

4. Check battery and replace if low or defective

1. Check to make sure check valves installed between primary

pump discharge and Backup Sump Pump are functioning
properly

1. Verify battery connection is correct

1. Check fuse and replace with a fuse of same rating and size
2. Check battery voltage. PS/BC will not charge batteries with a

combined voltage of 21.6 VDC or less

1. Connections not secure
2. Low or defective battery
3. Float switch stuck

4. Defective or blown fuse

1. Defective battery
2. Impeller is locked

1. Check valve missing or improperly

installed

2. Obstruction in discharge pipe

or pump inlet

3. Discharge pipe length and/or

height exceeds capacity of pump

4. Low or defective battery

1. Check valve problem

1. Battery connection problem

1. Blown pump fuse
2. Low battery voltage

Maintenance

(Continued)

3. Inspect the terminals and clamps

for corrosion and tightness. Clean
and tighten as required.

4. Unplug the main pump and fill sump

with water until back up pump turns
on. Repeat process two times to be
sure pump is operating normally.

5. If pump operates normally, plug

PS/BC into wall outlet, turn on main
pump. If pump fails to operate
normally, see Troubleshooting guide
and correct problem. Repeat step 5.