Troubleshooting – Badger Meter Registers User Manual
Page 13

TROUBLESHOOTING
Problem
Possible Causes
Remedies
Screen is blank
Battery is dead .
Replace battery .
Will not count in totalizer mode
1 . Improperly programmed .
2 . Broken or defective wiring .
3 . Improperly connected .
4 . Transmitter defective .
1 . Check programming .
2 . Check wiring .
3 . Check connections .
4 . Repair or replace transmitter .
Will not indicate rate of flow
1 . Improperly programmed .
2 . Improperly connected .
3 . Transmitter defective .
1 . Check programming .
2 . Check connections .
3 . Repair or replace transmitter .
Cannot program
Program-enable jumper is not installed or
is installed improperly .
Install jumper .
Cannot reset from front panel
Reset enable is not programmed .
Reprogram mode to ON
(Program Mode 7) .
Erroneous readings
1 . Improperly programmed .
2 . Defective transmitter .
1 . Check programming .
2 . Repair or replace transmitter .
No Pulse Output
1 . Defective output transistor .
2 . Improper wiring .
1 . Replace ER-9 .
2 . Check connections
Table 4: Troubleshooting
For further assistance, call our Technical Support Staff at 1-800-876-3837 .
User Manual
Page 13
March 2014
REG-UM-00836-EN-11