Select meter size, Select display function, Select units of measure – Badger Meter B2800 User Manual
Page 8: Select rate (time) interval

Programming
Keys
Mode
Indicator
Units Display
And
Programming Choices
Rate / Total Display
And
Programming Choices
RUN PROGRAM
RELAY1 RELAY2
Figure 2: B2800 flow monitor
Select Meter Size
At the METER prompt, press ENTER The current meter size number will begin to flash Using the arrow keys, scroll through the
size choices to select the bore size of your meter Press ENTER to save meter size choice
OTEE:
N
The meter connection size and the bore size are different For example, many of the one inch NPT turbines have bore
sizes that range from 3⁄8 inch up to 1 inch Be sure to use the correct bore size or the meter will report incorrect flows
and totals
Select Display Function
The monitor can display RATE or TOTAL or alternate between BOTH rate and total At the DISPLAY prompt, press ENTER once
The monitor now shows the display mode currently in effect To change to an alternate display mode, use the arrow keys to
scroll to the desired display mode and press ENTER to save the choice
Select Units of Measure
The monitor allows the choice of many common rate units (See
for a complete listing of the
unit choices ) At the RATE UNT prompt, press ENTER The monitor now shows the current rate unit If the current selection
is correct, press ENTER to advance to the next parameter To change to an alternate unit, use the arrow keys to scroll to the
desired rate unit and press ENTER to save the choice
Select Rate (Time) Interval
The term rate implies that something is occurring over a period of time Most people are familiar with the rate of speed of a
car reported in miles per hour (mph) The same concept holds true for a flow meter The time choices are SEC (seconds), MIN
(minutes), HOUR (hours), and DAY (days) At the RATE INT prompt, press ENTER The monitor now shows the current time
interval If the current selection is correct, press ENTER to advance to the next parameter To change to an alternate time
interval, use the arrow keys to scroll to the desired time interval and press ENTER to save the choice
OTEE:
N
If flow rate is the only measurement of interest, skip to KFAC UNT to complete the programming process
Flow Monitor, B2800 Flow Monitor – Advanced
Page 8
November 2013