Troubleshooting guide, Part number information, Replacement parts – Badger Meter B2800 User Manual
Page 20: Troubleshooting guide 20, Part number information 20, Replacement parts 20, B 28 a x x - c s

TROUBLESHOOTING GUIDE
Trouble
Remedy
No LCD Display
• Check battery voltage Should be 1 5V DC Replace if low or dead
No Rate or Total
Displayed
• Check connection from meter pickup to display input terminals
• Check turbine meter rotor for debris Rotor should spin freely
• Check programming of flow monitor
Flow Rate Display
Interprets Reading
Constantly
• This is usually an indication of external noise Keep all AC wires separate from DC wires
• Check for large motors close to the meter pickup
• Check for radio antenna in close proximity
• Try disconnecting the pickup from the monitor pig tail This should stop the noise
Flow Rate Indicator
Bounces
• This usually indicates a weak signal Replace pickup and/or check all connections
• Examine K factor
PART NUMBER INFORMATION
B 28 A X X - C S
Power Option
B - Battery
L - Loop
Program Level
A - Advanced
Mounting Style
M - Meter Mount
R - Remote Mount
S - Swivel Mount
H - Hand-Held
Units of Measure
CS - Customer Selectable
REPLACEMENT PARTS
Component
Part Number
Keypad
B260713
Battery
B280601
Battery Tie Wrap
B228036
Pickup Cable
B222-121
Desiccant Bag
B260630
PVC Union
B220016
PVC Reducer Bushing
B220056
Rubber Washer
B228207
Steel Lock Washer
B220018
PCB Shield (battery units)
B280603
Desiccant Shield
B280680
Cord Grip
B220103
Flow Monitor, B2800 Flow Monitor – Advanced
Page 20