CONNECT THE ORION REMOTE ENDPOINT TO A TWO-CONDUCTOR

CABLE FROM A METER OUTPUT

If connecting a endpoint to a pair of wires, determine the proper length of wire needed from the ORION remote

endpoint and from the pulser

1 Trim about 3/4 inch of the outer sheath from both ORION wires This exposes the two individual wires in each

NOTE:

N

Do not remove the insulation from these wires

2 Insert the two ORION remote endpoint positive (+) polarity wires into a gel cap Make sure the two wires are inserted

fully and seated in the gel cap

A three-wire gel cap should be used with the negative (-) polarity wire of the meter output going to the black and green wires

of the ORION unit

GAS RT CONNECTIONS

NOTE:

N

For detailed instructions, see the Model GAS RT Installation Data sheet

If a Badger Meter gas RT (Recordall® endpoint) is used as the source of the signal, the wires are spliced into the gas RT
The gas RT is installed on the index cover face

Gel-caps are provided for splicing ORION remote endpoint cables to gas RT cables

Gas RT

Gas RT Cover

Gas RT Attached to
the Index Cover Face

Two-Wire Gel
Cap for gas RT
Red Wire and
ORION Remote
Endpoint Red
Wire

Three-Wire Gel
Cap for gas
RT Black Wire,
ORION Remote
Endpoint
Black Wire and
ORION Remote
Endpoint Green
Wire