Read errors, Change current settings, Apply current settings – Badger Meter High Resolution LCD Encoders (HR-E LCD) User Manual
Page 17: Read errors 17

Installation and Programming Manual
Read Errors
If no COM port is selected, this error message displays In this case, click OK, select the correct COM port, and try the
Read again
If the wrong COM port is selected, this error message displays In this case, click Cancel, select the correct COM port, and try
the Read again
Change Current Settings
If you need to change the settings for the current encoder, follow this procedure
To set a default value for any of the data fields:
1 Click the down arrow to the right of the field to display a drop-down list of values
2 Click on the value you want to set as the default for that field
NOTE:
N
You must set the default value for the Meter Type field before you set the Meter Model / Size field
The Rate of Flow Units do not have to be the same as the Unit of Measure (even in a cubic foot meter, the
flow rate can be gallons per minute)
Apply Current Settings
When you click Apply Current Settings, the displayed settings are programmed into the encoder and the encoder goes into
storage mode In storage mode, the encoder displays the meter type and unit of measure In this example, a Model 25 Disc
Meter measured in gallons:
GAL
The software retains the current settings until you perform another Read
If you have multiple encoders to program with the same parameters, just attach the IR head bracket to them, one at a time,
and click Apply Current Settings
Page 17
December 2012