Badger Meter Recordall Transmitter Register (RTR) User Manual
Page 5

Installation Manual
CONNECTING THE INPUT 308 IN-LINE CONNECTOR TO AN RTR
To ensure the Badger Meter 308 in-line connector assembly is properly installed, follow these installation steps :
OTEE:
N
When installing a Summator product to a compound or fire series assembly, make sure the proper 308 in-line
connector is assembled to the appropriate high or low side RTR. The 308 in-line connector cables are labeled with
either a "HIGH FLOW" or "LOW FLOW" tag to assist with proper installation. Make sure the low flow cable is connected
to the low flow register and the high flow cable to the high flow register on the unit. When connecting to a single
register meter, make sure a single input Summator/Splitter is used.
1. Remove the waterproof protective cover from the connector by squeezing the ribbed areas together and pulling the cover
straight off the assembly. The cover should be able to be removed from the connector using very little force.
Male connector
Protective cover
Ribbed area on both sides of cover
Squeeze the ribbed area and
pull the cover straight off
Ribbed area on both
sides of connector
Female connector
Protective
cover
Squeeze the ribbed area and
pull the connector straight off
Figure 1: Connecting the input to an RTR
If any of the following conditions exist, do not continue with the installation of the connector assembly.
• Damaged or missing seal
• Cut or nicked cable, providing a potential tamper
OTEE:
N
The protective cover should be installed on the connector whenever it is not fully assembled to protect against
moisture and debris.