7. Verification Steps
The following steps can be used to verify and/or troubleshoot installations in the field. 
 
1. Verify that the staus of the loop start trunk connected to the 3226 Trunk Port FXO 
Doorphone is in-service using the status trunk command on Communication Manager. 
Below is the output of the command. 
status trunk 100 
 
 TRUNK GROUP STATUS 
 
Member Port Service State Mtce Connected Ports 
 Busy 
 
0100/001 001V208 in-service/idle no 
2. Verify that when the call button on the Door Station is pressed, the specified telephone on
Communication Manager rings, and upon answering the call, two-way audio path is 
established. 
 
3. Verify that the 3226 Trunk Port FXO Doorphone returns to the idle state when the call is 
terminated.
 
4. Verify that incoming calls to the 3226 Trunk Port FXO Doorphone are also successful. 
 
8. Conclusion
These Application Notes describe the administration steps required to integrate the Algo 3226 
Trunk Port FXO Doorphone with Avaya Aura® Communication Manager. Calls to the 3226 
Trunk Port FXO Doorphone were successful in both directions. In addition, unlocking a door 
using DTMF tones was successful. All test cases passed. 
9. Additional References
This section references documentation relevant to these Application Notes. The following Avaya 
product documentation is available a
 
[1] Administering Avaya Aura
TM
Communication Manager, June 2010, Release 6.0, Issue 6.0,
Document Number 03-300509.
 
The following Algo product documentation is available a
 
[2] Algo 3226 Trunk Port FXO Doorphone Installation and User Guide, Document Number 90-
00040A.